A failure has been detected in the electronics module. Causes range from an incorrect electronics module being installed, poor trailing cable connections or a failed electronics module. Follow the instructions below to solve the problem.
NOTE: This particular system error will typically have a sub code of 0x401006, Line 3374.
Contact center agents (troubleshooting to be performed with customer)
The steps below are designed to achieve remote resolution of the issue. If the troubleshooting steps below appear to resolve the issue, attempt to verify printer functionality by printing several internal prints. If the issue persists following the steps below, generate a CSO for service.
Parts required (part numbers are subject to change)
|
Designjet 500 Model Numbers - C7769B, C7770B, C7769C, C7770C |
|
Trailing Cable (Required) |
||
Electronic Module (Required) |
If any of the troubleshooting steps listed below solve the problem, attempt to verify functionality. If functionality is verified, no additional parts should be replaced.
WARNING: To prevent possible injury, always remove the power cable from the back of the printer before connecting/disconnecting any internal printer cables or performing any repairs.
NOTE: Ensure a good connection has been obtained. A very high percentage of these systems errors are solved by properly re-seating the trailing cable.
Verifying printer functionality